With high permeability permalloy core with epoxy potting,
products features on high precision, excellent linear performance,
well-insulation, low profile etc.
Part
Number
Turns
Inductance
(17.5 HZ )
Current
( Amp ) MAX.
Sensitivity
Terminating
Resistor (Ohm)
Vout (V)
In (A )
TCP2M5-00
50
5
10
1
1
50
TCP2M20-00
100
20
24
1
1
100
TCP2M80-00
200
80
35
1
1
200
TCP2M1125-00
750
1125
30
1
1
750
SMD Current Sense Transformer
Feature
Low profile surface mount with integrated current detecting
turn
Designed for switch mode power supply application
Compatible with surface mount process temperatures
UL class H 180¢XC
Application
Switching power supplies
AC current detection
Output supply for control circuitry
Appliance,medical equipment,office equipment
ECL P/N
I Primary
RMS
(Amp)
Secondary Inductance
(mH Min.)
Secondary D.C.
Resistance
(£[+- 15%)
Ratio
N to 1
Isolation
Size
Inches
PDF
Download
SCT02-070
6
0.98
4.52
70
500 V
0.325x0.260x0.228
SCT03-070
6
0.98
4.1
70
500 V
0.325x0.260x0.181
SCT04-200
6
8
14
200
500 V
0.325x0.260x0.228
SCT13-070
20
0.98
4.52
70
500 V
0.325x0.260x0.228
SCT14-070
20
0.98
4.1
70
500 V
0.325x0.260x0.181
SCT15-100
20
2
6.09
100
500 V
0.325x0.260x0.228
SCT16-100
20
1.9
6.3
100
1500 V
0.325x0.260x0.228
Turns Ratios up to 200 are available. Consult factory if your required
turns ratio is not in this table